Introduction

The pin index safety system (PISS) is a precise configuration of pins and holes that facilitate the connection between a specific medical gas cylinder and the delivery system of these gases.[1] This system was devised to prevent the unintentional placement of a cylinder of the wrong medical gas onto the hanger yoke of the anesthesia machine that was designed for another gas. While this system provides an element of safety, it does not eliminate the possibility of administration of incorrect gas.[2]

System Overview

Typically, the medical gasses supplied to anesthesia machines or workstations are delivered via pipeline from a central piping system. The most commonly used gases are oxygen, medical air, and nitrous oxide; however, when gas delivered via pipeline is contaminated, fails, or is unavailable, cylinders containing medical gas may be used as an alternative source. Orientation and support of the cylinder are provided by the hanger yoke assembly of the anesthesia machine. Unidirectional airflow and effective seal are also set by the hanger yoke, and without appropriately placed pins on both the cylinder and yoke, an appropriate seal is not achieved. A special washer or gasket[1] is used to attain this seal as described below. This system is often utilized for E-cylinders or smaller sizes[3] and is specific for the high-pressure systems within the machine.

History

The first anesthetic machine, known as the Boyle apparatus, was debuted in 1917; however, the PISS was not instituted until the 1950s. Before the use of the PISS, gases were differentiated from each other by the colors of the cylinders and tubing. To prevent the incorrect tubing from being attached to the cylinder (through either human error or old tubing losing its distinctive and critical color), the Ministry of Health in Great Britain[3] instituted the PISS to try to minimize patient accidents. 

Major organizations, including the American Society of Anesthesiologists (ASA), were made aware of the vulnerabilities of medical gas delivery systems during World War II. This war resulted in a high volume of surgeries that manifested the need for an improvement in anesthetic and surgical safety.[4] The PISS now allowed gas cylinders to be fitted with non-interchangeable pin index valves that were specific to the cylinder of a particular medical gas. Such a system was meant to reduce the probability of a medical gas cylinder being improperly connected to the delivery system. The decision was made to install this type of system as it could be easily fitted to the machines without requiring a complete overhaul by the manufacturers; instead, it could be fitted by modifying the hardware that already existed, thereby reducing cost and streamlining implementation. Although it had previously been considered a "fool-proof" safety mechanism, examples of failures, such as those described below, have led to quality control improvements and improved safety measures.

Function

Pin Index Configurations for Commonly Used Medical Gases

Each pin index safety system (PISS) has six possible pin placement sites, depending on the gas within the cylinder. The pins protrude from the gas tank yokes and fit corresponding holes in the cylinder valves, providing a mostly "fool-proof" way of connecting the appropriate gas to the appropriate valve. Two pins will be placed per cylinder, allowing for multiple, medically used gases that have been added to the standard formats. The following are examples of pin locations for gases:

  • Oxygen: 2, 5
  • Nitro Oxide: 3, 5
  • Air: 1, 5 (Figure 1)
  • Carbon Dioxide: 1, 6
  • Nitrogen: 1, 4

These numbers describe the location of the pins in millimeters from the edge of the yoke,[3] with pin #1 being the farthest to the right when looking at the system straight on. The first pin is located 30 degrees from horizontal on the gas tank yoke, and each subsequent pin is located 12 degrees further down, creating a semi-circle. These numbers and pin placements are standardized across countries.

Issues of Concern

Multiple documented cases of pin index safety system (PISS) failure resulting in patient injury have led to quality improvements in the system. An early flaw was noted by Pauling in 1983 when a patient died after erroneously being given 100% nitrous oxide throughout the case instead of oxygen due to the crossing of the pipelines. In the weeks leading up to the case, a maintenance team in the hospital had stripped the gas line threads in an attempt to replace valves but did not independently test the gases that were able to flow through each line after the work was complete.[5] This case highlights how important it is to ensure proper valve/pin placement and be aware that incorrect setup of any valves further up the line can cause the system to fail.

A second case report in 1995 documented an incident in which a woman undergoing a laparoscopic cholecystectomy sustained an intraabdominal fire after a trochar caught fire, leading to ignition of the insufflating gas within the abdomen. Post-incident analysis revealed that the company providing the gas had a policy that a canister with greater than 7% CO2 would be fitted with a CO2 pin index; however, this canister had a green stripe around the top to identify it as having majority O2, not CO2. This particular canister that was being used in the OR happened to be 14% CO2 and 86% O2, leading to the OR fire. This incident also highlighted the influence of human error in the PISS as well as the potential downfalls of the system.[2] Subsequently, efforts were made to distinguish O2 from CO2 and the need for further oversight was proven.

Clinical Significance

In each of the above cases, an investigation was undertaken to determine the cause and prevent a recurrence of each event. While the pin index safety system (PISS) is only used on smaller cylinders, the success of this system was eventually adapted to larger systems, resulting in some countries requiring even larger cylinders to be pin-indexed. The crossing of pipelines in hospitals has resulted in more oversight by maintenance crews, and the mislabeling of canisters has since been addressed. While this system has clearly been designed to help improve safety outcomes, it cannot be overstated that clinical oversight of medical equipment is a vitally important part of patient safety.


  • Image 6744 Not availableImage 6744 Not available
    Contributed by Sandeep Dhanjal, MD
Attributed To: Contributed by Sandeep Dhanjal, MD

Interested in Participating?

We are looking for contributors to author, edit, and peer review our vast library of review articles and multiple choice questions. In as little as 2-3 hours you can make a significant contribution to your specialty. In return for a small amount of your time, you will receive free access to all content and you will be published as an author or editor in eBooks, apps, online CME/CE courses, and an online Learning Management System for students, teachers, and program directors that allows access to review materials in over 500 specialties.

Improve Content - Become an Author or Editor

This is an academic project designed to provide inexpensive peer-reviewed Apps, eBooks, and very soon an online CME/CE system to help students identify weaknesses and improve knowledge. We would like you to consider being an author or editor. Please click here to learn more. Thank you for you for your interest, the StatPearls Publishing Editorial Team.

Pin Index Safety - Questions

Take a quiz of the questions on this article.

Take Quiz
Which system prevents a cylinder of the wrong type of medical gas from being attached to equipment designed to deliver gases?



Click Your Answer Below


Would you like to access teaching points and more information on this topic?

Improve Content - Become an Author or Editor and get free access to the entire database, free eBooks, as well as free CME/CE as it becomes available. If interested, please click on "Sign Up" to register.

Purchase- Want immediate access to questions, answers, and teaching points? They can be purchased above at Apps and eBooks.


Sign Up
Which of the following safety systems are displayed in this image (yellow arrow)?

(Move Mouse on Image to Enlarge)
  • Image 6743 Not availableImage 6743 Not available
    Contributed by Sandeep Dhanjal, MD
Attributed To: Contributed by Sandeep Dhanjal, MD



Click Your Answer Below


Would you like to access teaching points and more information on this topic?

Improve Content - Become an Author or Editor and get free access to the entire database, free eBooks, as well as free CME/CE as it becomes available. If interested, please click on "Sign Up" to register.

Purchase- Want immediate access to questions, answers, and teaching points? They can be purchased above at Apps and eBooks.


Sign Up
The Pin-Index Safety system (PISS) reduces the chance that the wrong gas is delivered to the patient from a medical gas cylinder. However, Which of the following represents a way in which an incorrect gas may still be delivered to the patient even when the anesthesia machine has a PISS?



Click Your Answer Below


Would you like to access teaching points and more information on this topic?

Improve Content - Become an Author or Editor and get free access to the entire database, free eBooks, as well as free CME/CE as it becomes available. If interested, please click on "Sign Up" to register.

Purchase- Want immediate access to questions, answers, and teaching points? They can be purchased above at Apps and eBooks.


Sign Up
Which of the following is a potential consequence of attaching the wrong medical gas cylinder to the anesthesia machine?



Click Your Answer Below


Would you like to access teaching points and more information on this topic?

Improve Content - Become an Author or Editor and get free access to the entire database, free eBooks, as well as free CME/CE as it becomes available. If interested, please click on "Sign Up" to register.

Purchase- Want immediate access to questions, answers, and teaching points? They can be purchased above at Apps and eBooks.


Sign Up
Which of the following is not a component of the pin-index safety system (PISS)?



Click Your Answer Below


Would you like to access teaching points and more information on this topic?

Improve Content - Become an Author or Editor and get free access to the entire database, free eBooks, as well as free CME/CE as it becomes available. If interested, please click on "Sign Up" to register.

Purchase- Want immediate access to questions, answers, and teaching points? They can be purchased above at Apps and eBooks.


Sign Up
Which system refers to the safety interface between the gas delivery system and the medical gas cylinders?



Click Your Answer Below


Would you like to access teaching points and more information on this topic?

Improve Content - Become an Author or Editor and get free access to the entire database, free eBooks, as well as free CME/CE as it becomes available. If interested, please click on "Sign Up" to register.

Purchase- Want immediate access to questions, answers, and teaching points? They can be purchased above at Apps and eBooks.


Sign Up

Pin Index Safety - References

References

Srivastava U, Anaesthesia gas supply: gas cylinders. Indian journal of anaesthesia. 2013 Sep     [PubMed]
Greilich PE,Greilich NB,Froelich EG, Intraabdominal fire during laparoscopic cholecystectomy. Anesthesiology. 1995 Oct     [PubMed]
Donaldson M,Donaldson D,Quarnstrom FC, Nitrous oxide-oxygen administration: when safety features no longer are safe. Journal of the American Dental Association (1939). 2012 Feb     [PubMed]
Hogg CE, Pin-indexing failures. Anesthesiology. 1973 Jan     [PubMed]
Pauling M,Ball CM, Delivery of anoxic gas mixtures in anaesthesia: case report and review of the struggle towards safer standards of care. Anaesthesia and intensive care. 2017 Mar     [PubMed]

Disclaimer

The intent of StatPearls is to provide practice questions and explanations to assist you in identifying and resolving knowledge deficits. These questions and explanations are not intended to be a source of the knowledge base of all of medicine, nor is it intended to be a board or certification review of Nurse Anesthetist. The authors or editors do not warrant the information is complete or accurate. The reader is encouraged to verify each answer and explanation in several references. All drug indications and dosages should be verified before administration.

StatPearls offers the most comprehensive database of free multiple-choice questions with explanations and short review chapters ever developed. This system helps physicians, medical students, dentists, nurses, pharmacists, and allied health professionals identify education deficits and learn new concepts. StatPearls is not a board or certification review system for Nurse Anesthetist, it is a learning system that you can use to help improve your knowledge base of medicine for life-long learning. StatPearls will help you identify your weaknesses so that when you are ready to study for a board or certification exam in Nurse Anesthetist, you will already be prepared.

Our content is updated continuously through a multi-step peer review process that will help you be prepared and review for a thorough knowledge of Nurse Anesthetist. When it is time for the Nurse Anesthetist board and certification exam, you will already be ready. Besides online study quizzes, we also publish our peer-reviewed content in eBooks and mobile Apps. We also offer inexpensive CME/CE, so our content can be used to attain education credits while you study Nurse Anesthetist.